How do you convert relative humidity (%) to absolute humidity (g/m³)?
Three steps, and the only difficulty is unit bookkeeping.
Step 1 — saturation vapour pressure at the air temperature.
Step 2 — actual vapour pressure. Multiply by the relative humidity as a fraction:
Step 3 — apply the ideal gas law to the vapour.
Worked through
Air at 23.9°C, 60% relative humidity.
- eₛ = 6.112 × exp(17.62 × 23.9 / 267.02) = 29.6 hPa
- e = 29.6 × 0.60 = 17.8 hPa = 1,780 Pa
- ρᵥ = 1,780 / (461.5 × 297.05) × 1000 = 12.9 g/m³
How do you convert absolute humidity (g/m³) back to relative humidity (%)?
The same chain reversed. Note you still need the temperature — a quantity of water is not a percentage of anything until you know what the ceiling is.
- Vapour pressure from density: e = ρᵥ / 1000 × 461.5 × (T + 273.15), then ÷100 for hPa.
- Saturation pressure at the same temperature, as above.
- Divide and scale: RH = 100 × e / eₛ(T).
Cap the answer at 100%. A figure above saturation means liquid water suspended in the air — fog — rather than a humidity above 100%.
How can you write the conversion as one spreadsheet formula?
With temperature in Celsius in A1 and relative humidity in percent in B1:
And the reverse, with g/m³ in A1 and temperature in Celsius in B1:
Which three unit traps cause humidity conversion errors?
Almost every wrong answer in this conversion comes from one of these:
- Celsius and kelvin in the same calculation. Magnus wants Celsius. The gas law wants kelvin. Both appear in step 3.
- Hectopascals and pascals. Meteorology quotes hPa; the gas constant expects Pa. Factor of 100.
- Kilograms and grams. The gas law gives kg/m³. Everyone quotes g/m³. Factor of 1000.
Get all three right and the answer is correct to well under a percent. Get one wrong and it will be out by a factor of 100 or 1000, which at least makes the mistake obvious.
When should you use the mixing ratio (g/kg) instead of g/m³?
If the reason for converting is to compare two air masses, be aware that g/m³ is a density and drifts slightly as air expands. The mixing ratio in g/kg does not, and its conversion is w = 621.97 × e / (p − e) — one step from the same vapour pressure, but it needs the station pressure.
For a single reading at ground level the difference does not matter. For following one parcel of air around, it does.